Failure Phenomenon And Cause Analysis Of Ultra-high Pressure Hand Pump

                  Failure phenomenon and cause analysis of ultra high Pressure manual pump: Find the cause of the failure from the following three points during maintenance and improve the system:

                  (1) Check the internal leakage of the movable arm cylinder. The easiest way to do this is to raise the arm to see if there is a noticeable drop in freedom. If the whereabouts of the obvious removal of ultra-high pressure manual pump cylinder inspection, seal ring if worn should be replaced.Hand Pump

                  (2) Check the control valve. First cleaning safety valve, check whether the valve core wear, such as wear should be replaced. If the safety valve is not changed after installation, then check the control valve spool wear condition, its clearance use limit is generally 0.06mm, wear seriously should be replaced.Hand Pump

                 (3) measure the pressure of ultra-high pressure manual pump. If the pressure is low, then the adjustment, add pressure is still not up, then the hydraulic pump serious wear. In general, the main reasons for the inability to lift the arm belt are: a. The hydraulic pump is badly worn. In the low-speed operation of the pump leakage is serious; high-speed operation, ultra-high pressure manual pump slightly improve, but because of the pump wear and leakage, volume efficiency significantly reduced, difficult to achieve the rated pressure. Long-time hydraulic pump work and increased wear, oil temperature rise, resulting in hydraulic components wear and sealing parts of aging, damage, loss of sealing capacity, hydraulic oil deterioration, and finally lead to failure. B. The selection of hydraulic components is unreasonable. Dynamic arm cylinder size of 70/40 non-standard series, seals are not standard parts, high cost and inconvenience of sealing parts replacement. The cylinder diameter of the movable arm oil cylinder is small, which will make the system adjust the pressure high. C. Ultra high pressure manual pump hydraulic system design is unreasonable. Control valve and full hydraulic steering gear for single Pump series, the relief valve to adjust the pressure of 16MPa, and the hydraulic pump rated working pressure is 16MPa. Hydraulic pump often in full load or long time overload (high pressure), and the system has a hydraulic impact, long-term oil, hydraulic oil pollution, aggravate the hydraulic pump wear, so that the hydraulic pump shell burst (after the failure of this type).Hand Pump


Feedback

If you have any enquiry about quotation or cooperation, please feel free to email us at info@wrenchina.com or use the following enquiry form. Our sales representative will contact you within 24 hours. Thank you for your interest in our products.

Contact Us
Address: No.24, Xingxing Road, Xingqiao, Yuhang, Hangzhou, China
Tel: +86-571-88115720
Fax: +86-571-88110210
E-mail:info@wrenchina.com
Home | About Us | Products | News | Knowledge | Contact Us | Feedback | Mobile | XML